DIP 8 Optocoupler VO2223A-X001 with 5300 Volt Input to Output Isolation and Low LED Trigger Current
Vishay Semiconductors VO2223A Optocoupler, Power Phototriac
The VO2223A is an optically coupled phototriac designed to drive a power triac. It offers 5300 V of input-to-output isolation and is suitable for various home appliance and industrial equipment applications. Key features include a low maximum trigger current of 10 mA, a peak off-state voltage of 600 V, and a load current of 1 ARMS.
Product Attributes
- Brand: Vishay Semiconductors
- Package: DIP-8
- Material: Pure tin leads
- Agency Approvals: UL / cUL 1577, DIN EN 60747-5-5 (VDE 0884-5)
Technical Specifications
| Parameter | Test Condition | Symbol | Min. | Typ. | Max. | Unit |
| INPUT | ||||||
| LED trigger current | VT = 6 V | IFT | 2.5 | - | 10 | mA |
| Input reverse current | VR = 5 V | IR | - | - | 10 | A |
| LED forward voltage | IF = 10 mA | VF | 0.9 | - | 1.4 | V |
| OUTPUT | ||||||
| Peak on-state voltage | ITM = 1 A | VTM | - | - | 1.7 | V |
| Peak off-state current | VDRM = 600 V, TA = 110 C | IDRM | - | - | 100 | A |
| Holding current | RL = 100 | IH | - | - | 25 | mA |
| Critical rate of rise of off-state voltage | VIN = 400 VRMS (Fig. 3) | dV/dtcr | - | 210 | - | V/s |
| Critical rate of rise of commutating voltage | VIN = 240 VRMS, IT = 1 ARMS (Fig. 3) | dV/dtcrq | - | 0.7 | - | V/s |
| COUPLER | ||||||
| Total power dissipation | (2) | Pdiss | - | - | 1.2 | W |
| Isolation test voltage | For 1 s | VISO | - | 5300 | - | VRMS |
| SAFETY AND INSULATION RATINGS | ||||||
| Climatic classification | IEC 68 part 1 | - | 40 / 85 / 21 | - | - | - |
| Pollution degree | DIN VDE 0109 | - | 2 | - | - | - |
| Tracking resistance (comparative tracking index) | Insulation group IIIa | CTI | 175 | - | - | - |
| Highest allowable overvoltage | Transient overvoltage | VIOTM | 8000 | - | - | Vpeak |
| Maximum working insulation voltage | Recurring peak voltage | VIORM | 890 | - | - | Vpeak |
| Insulation resistance at 25 C | VIO = 500 V | RIS | 1012 | - | - | |
| Insulation resistance at TS | VIO = 500 V | RIS | 109 | - | - | |
| Insulation resistance at 100 C | VIO = 500 V | RIS | 1011 | - | - | |
| Partial discharge test voltage | Method b, Vpd = VIORM x 1.6 | Vpd | - | 1424 | - | Vpeak |
| Safety limiting values - maximum values allowed in the event of a failure | Case temperature | TSI | - | - | 165 | C |
| Safety limiting values - maximum values allowed in the event of a failure | Input current | ISI | - | - | 150 | mA |
| Safety limiting values - maximum values allowed in the event of a failure | Output power | PSO | - | - | 2000 | mW |
| Minimum external air gap (clearance distance) | Measured from input terminals to output terminals, shortest distance through air | - | 7 | - | - | mm |
| Minimum external tracking (creepage distance) | Measured from input terminals to output terminals, shortest distance path along body | - | 7 | - | - | mm |