Broadcom ACNT H50L 500E optocoupler certified to UL1577 and IEC standards for safe in power electronics
Product Overview
The Broadcom ACNT-H50L is a high-speed, single-channel 1-MBd optocoupler designed for isolated communication logic interfaces and control in high-voltage power systems. Utilizing a Stretched SO8 footprint and advanced insulation technology, it provides robust electrical isolation. The optocoupler features separate connections for the photodiode bias and output transistor collector, significantly increasing speed compared to conventional photo-transistor couplers. With 15-mm creepage/clearance and high-voltage insulation capabilities, it is ideal for applications such as 690VAC drives, renewable energy inverters, and medical equipment, ensuring reliable performance across a wide temperature range and meeting stringent safety standards.
Product Attributes
- Brand: Broadcom
- Certifications: UL1577 recognized (7500VRMS for 1 minute), CSA approval, IEC 60747-5-5 approval for reinforced insulation
- Package: 15-mm Stretched SO8
- Material Group: IIIa (DIN VDE 0110, 1/89)
- Installation Classification: I IV (per DIN VDE 0110/39)
- Climatic Classification: 40/105/21
- Pollution Degree: 2 (DIN VDE 0110/39)
Technical Specifications
| Parameter | Symbol | Min. | Typ. | Max. | Unit | Conditions | Figure |
|---|---|---|---|---|---|---|---|
| High speed | 1 | Mb/s | |||||
| Package Dimensions | 15-mm | Stretched SO8 | |||||
| Common-Mode Rejection | 15 | kV/s | VCM = 1500V | ||||
| Operating Temperature Range | TA | -40 | 105 | C | |||
| Input-Output Momentary Withstand Voltage | VISO | 7500 | Vrms | t = 1 min. | |||
| External Clearance | L(101) | 14.2 | mm | ||||
| External Creepage | L(102) | 15 | mm | ||||
| Internal Plastic Gap | 0.5 | mm | |||||
| Tracking Resistance (CTI) | CTI | >300 | V | DIN IEC 112/VDE 0303 Part 1 | |||
| Maximum Working Insulation Voltage | VIORM | 2262 | Vpeak | ||||
| Input-Output Resistance | R I-O | 1014 | V I-O = 500V DC | ||||
| Input-Output Capacitance | C I-O | 0.6 | pF | f = 1 MHz, TA = 25C | |||
| Supply Voltage | VCC | 3.0 | 24 | V | |||
| Current Transfer Ratio (CTR) | 31 | 50 | 80 | % | TA = 25C, VO = 0.4V, VCC = 3.3V or 5V, IF= 12 mA | Figure 2, Figure 3 | |
| Logic Low Output Voltage | VOL | 0.2 | 0.4 | V | TA = 25C, IO = 3 mA, VCC = 3.3V or 5V, IF = 12 mA | ||
| Propagation Delay Time to Logic Low at Output | TPHL | 0.1 | 0.8 | s | TA = 25C, VCC = 3.3V, RL = 1.0 k, CL = 15 pF, VTHHL = 1.5V | Figure 15 | |
| Propagation Delay Time to Logic High at Output | TPLH | 0.4 | 1.0 | s | TA = 25C, VCC = 3.3V, RL = 1.0 k, CL = 15 pF, VTHLH = 2.0V | Figure 15 | |
| Common-Mode Transient Immunity at Logic High Output | |CMH| | 15 | 40 | kV/s | TA = 25C, VCM = 1500V, IF = 0 mA | Figure 16 | |
| Common-Mode Transient Immunity at Logic Low Output | |CML| | 15 | 40 | kV/s | TA = 25C, VCM = 1500V, IF = 12 mA | Figure 16 |
Applications
- High-voltage power systems (e.g., 690VAC drives)
- Renewable energy inverters
- Feedback elements in switching power supplies
- Digital isolation for A/D, D/A conversion digital field
- Communications interface
- MCU interface
2410121746_Broadcom-ACNT-H50L-500E_C691913.pdf
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.