Isolated interface optocoupler Broadcom ACNT-H61L-500E with CMOS output and RoHS 6 compliant options
Product Overview
The Broadcom ACNT-H61L is a stretched wide optically coupled optocoupler designed for low-power isolated interface applications. It integrates a light-emitting diode and a high-gain photo detector, consuming a maximum of 2 mA power supply current and operating with an input LED forward current as low as 4.5 mA. This optocoupler supports both 3.3V and 5V supply voltages with guaranteed AC and DC parameters across a wide temperature range of -40C to +105C. Featuring a CMOS output and an internal Faraday shield for superior common-mode transient immunity (20 kV/s), the ACNT-H61L is housed in a 15-mm stretched SO-8 package. Its high voltage insulation capability makes it suitable for isolated communication logic interfaces and control in high-voltage power systems, including 690VAC drives, renewable energy inverters, and medical equipment.
Product Attributes
- Brand: Broadcom
- Package Type: 15-mm stretched SO-8
- Certifications: UL 1577 recognized (7500 Vrms for 1 minute), CSA approval, IEC/EN 60747-5-5 (VIORM = 2262 Vpeak for reinforced insulation)
- Compliance: RoHS 6 fully compliant options available (-xxxE denotes lead-free product)
Technical Specifications
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Absolute Maximum Ratings | ||||||
| Storage Temperature | TS | 55 | 125 | C | ||
| Operating Temperature | TA | 40 | 105 | C | ||
| Reverse Input Voltage | VR | 5 | V | |||
| Supply Voltage | VDD | 6.5 | V | |||
| Average Forward Input Current | IF | 10 | mA | |||
| Peak Forward Input Current | IF(TRAN) | 1 | A | <1 s Pulse Width, <300 pulses per second | ||
| 80 | mA | <1 s Pulse Width, <10% Duty Cycle | ||||
| Output Current | IO | 10 | mA | |||
| Output Voltage | VO | 0.5 | VDD + 0.5 | V | ||
| Input Power Dissipation | PI | 20 | mW | |||
| Output Power Dissipation | PO | 22 | mW | |||
| Lead Solder Temperature | TLS | 260 | C | for 10 sec., 1.6 mm below seating plane | ||
| Recommended Operating Conditions | ||||||
| Operating Temperature | TA | 40 | 105 | C | ||
| Input Current, Low Level | IFL | 0 | 250 | A | ||
| Input Current, High Level | IFH | 4.5 | 8 | mA | ||
| Power Supply Voltage | VDD | 2.7 | 5.5 | V | ||
| Forward Input Voltage (OFF) | VF (OFF) | 0.8 | V | |||
| Electrical Specifications (DC) | ||||||
| Input Forward Voltage | VF | 1.20 | 1.38 | 1.85 | V | IF = 7 mA (Fig. 1, 2) |
| Input Reverse Breakdown Voltage | BVR | 7 | V | IR = 10 A | ||
| Logic High Output Voltage | VOH | VDD 0.1 | VDD | V | IF = 0 mA, VI = 0V, IO = 20 A | |
| VDD 1.0 | VDD | V | IF = 0 mA, VI = 0V, IO = 3.2 mA | |||
| Logic Low Output Voltage | VOL | 0.02 | 0.1 | V | IF = 7 mA, VI = 5V/3.3V, IO = 20 A | |
| 0.2 | 0.4 | V | IF = 7 mA, VI = 5V/3.3V, IO = 3.2 mA | |||
| Input Threshold Current | ITH | 0.7 | 3.8 | mA | (Fig. 3) | |
| Logic Low Output Supply Current | IDDL | 1 | 2 | mA | (Fig. 4) | |
| Logic High Output Supply Current | IDDH | 1 | 2 | mA | (Fig. 5) | |
| Input Capacitance | CIN | 20 | pF | f = 1 MHz, VF = 0V | ||
| Input Diode Temperature Coefficient | VF/TA | 1.5 | mV/C | IF = 7 mA | ||
| Switching Specifications (AC) | ||||||
| Propagation Delay Time to Logic Low Output | tPHL | 40 | 100 | ns | IF = 7 mA, VI = 3.3V/5V, CL= 15 pF, CMOS Signal Levels (Figs. 6, 7, 8, 9) | |
| Propagation Delay Time to Logic High Output | tPLH | 40 | 100 | ns | IF = 7 mA, VI = 3.3V/5V, CL= 15 pF, CMOS Signal Levels (Figs. 6, 7, 8, 9) | |
| Pulse Width | tPW | 100 | ns | |||
| Pulse Width Distortion | PWD | 5 | 40 | ns | |tPHL tPLH| | |
| Propagation Delay Skew | tPSK | 40 | ns | Magnitude of worst-case difference in tPHL and/or tPLH between units | ||
| Output Rise Time (10% to 90%) | tR | 10 | ns | |||
| Output Fall Time (90% to 10%) | tF | 10 | ns | |||
| Static Common-Mode Transient Immunity at Logic High Output | | CMH | | 20 | 35 | kV/s | VCM = 1000V, TA = 25C, IF = 0 mA, VI = 0V, CL= 15 pF, CMOS Signal Levels | |
| Static Common-Mode Transient Immunity at Logic Low Output | | CML | | 20 | 35 | kV/s | VCM = 1000 V, TA = 25C, IF = 7 mA, VI = 5V/3.3V, CL= 15 pF, CMOS Signal Levels | |
| Dynamic Common-Mode Transient Immunity | CMRD | 35 | kV/s | VCM = 1000V, TA = 25C, IF = 7 mA, VI = 5V/3.3V, 10-MBd data rate, absolute increase of PWD <10 ns | ||
| Package Characteristics | ||||||
| Input-Output Insulation | VISO | 7500 | Vrms | RH < 50% for 1 min. TA = 25C | ||
| Input-Output Resistance | RI-O | 1012 | VI-O = 500V | |||
| Input-Output Capacitance | CI-O | 0.6 | pF | f = 1 MHz, TA = 25C | ||
| Insulation and Safety Related Specifications (IEC/EN 60747-5-5) | ||||||
| Minimum External Air Gap (External Clearance) | L(101) | 14.2 | mm | Measured from input terminals to output terminals, shortest distance through air. | ||
| Minimum External Tracking (External Creepage) | L(102) | 15 | mm | Measured from input terminals to output terminals, shortest distance path along body. | ||
| Minimum Internal Plastic Gap (Internal Clearance) | 0.5 | mm | Through insulation distance conductor to conductor. | |||
| Tracking Resistance (Comparative Tracking Index) | CTI | >300 | V | DIN IEC 112/VDE 0303 Part 1. | ||
| Material Group (DIN VDE 0110, 1/89, Table 1.) | IIIa | |||||
| Installation Classification per DIN VDE 0110/39, Table 1 for rated mains voltage 600 Vrms | I IV | |||||
| Installation Classification per DIN VDE 0110/39, Table 1 for rated mains voltage 1000 Vrms | I IV | |||||
| Climatic Classification | 40/105/21 | |||||
| Pollution Degree (DIN VDE 0110/39) | 2 | |||||
| Maximum Working Insulation Voltage | VIORM | 2262 | Vpeak | |||
| Input to Output Test Voltage, Method ba | VPR | 4241 | Vpeak | VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC | ||
| Input to Output Test Voltage, Method aa | VPR | 3619 | Vpeak | VIORM x 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial Discharge < 5 pC | ||
| Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec) | VIOTM | 12000 | Vpeak | |||
| Safety-limiting Values Maximum Values Allowed in the Event of a Failure Case | ||||||
| Temperature | 150 | C | ||||
| Input Current | TS | 400 | mA | |||
| Output Power | IS, INPUT | 1000 | mW | |||
| Insulation Resistance at TS, VIO = 500V | RS | >109 | ||||
Applications
- Communication Interface: RS-485, CAN bus
- Digital isolation for A/D, D/A conversion
- High-voltage power systems, e.g., 690V drives
- Renewable energy inverters
- Medical imaging and patient monitoring