High peak output current optocoupler Broadcom ACNT-H313-000E designed for power IGBT and MOSFET driving in inverters

Key Attributes
Model Number: ACNT-H313-000E
Product Custom Attributes
Operating Temperature:
-40℃~+105℃
Isolation Voltage(Vrms):
7.5kV
Voltage - Supply:
1.45V
Number Of Channels:
1
Mfr. Part #:
ACNT-H313-000E
Package:
SOIC-8-13.6mm
Product Description

Product Overview

The Broadcom ACNT-H313 is an optocoupler featuring an LED optically coupled to an integrated circuit with a power output stage. It is specifically designed for driving power IGBTs and MOSFETs in motor control inverter applications. The device offers a high operating voltage range and high peak output current, enabling direct IGBT driving or the driving of discrete power stages for higher-rated IGBTs. With a high insulation voltage of VIORM = 2262 VPEAK (IEC/EN/DIN EN 60747-5-5), it is suitable for high power systems, AC and brushless DC motor drives, renewable energy inverters, industrial inverters, and switching power supplies.

Product Attributes

  • Brand: Broadcom
  • Package: 15-mm Stretched SO8
  • Certifications: UL Recognized (7500 VRMS for 1 min), CSA, IEC/EN/DIN EN 60747-5-5
  • Temperature Range: Industrial (40C to 105C)

Technical Specifications

Specification Symbol Min. Typ. Max. Units Conditions
Maximum Peak Output Current IOH(PEAK) 2.5 A Pulse width = 10 ms
Minimum Peak Output Current IOH(PEAK) 2.0 A
Maximum Propagation Delay (High Output) tPLH 0.28 0.50 s Rg = 10 , Cg = 10 nF, f = 10 kHz, Duty Cycle = 50%, IF = 7 mA to 12 mA, VCC = 15V to 30V
Maximum Propagation Delay (Low Output) tPHL 0.30 0.50 s Rg = 10 , Cg = 10 nF, f = 10 kHz, Duty Cycle = 50%, IF = 7 mA to 12 mA, VCC = 15V to 30V
Maximum Propagation Delay Difference (Between Any Two Parts) PDD -0.35 0.35 s
Minimum Common Mode Rejection (CMR) at VCM = 2000V |CMH|, |CML| 40 50 kV/s TA = 25 C, VCC = 30V
Maximum Supply Current ICCH, ICCL 5.0 mA Output Open
Under Voltage Lock-Out (UVLO) Threshold (High) VUVLO+ 11.0 12.3 13.5 V VO > 5V, IF = 10 mA
Under Voltage Lock-Out (UVLO) Threshold (Low) VUVLO- 9.5 10.7 12.0 V
UVLO Hysteresis UVLOHYS 1.6 V
Wide Operating VCC Range (VCC VEE) 15 30 V
Operating Temperature TA 40 105 C
Maximum Working Insulation Voltage VIORM 2262 VPEAK IEC/EN/DIN EN 60747-5-5
Input-Output Momentary Withstand Voltage VISO 7500 VRMS t = 1 min., TA = 25C, RH < 50%
Minimum External Air Gap (Clearance) L(101) 14.2 mm
Minimum External Tracking (Creepage) L(102) 15 mm
Tracking Resistance (Comparative Tracking Index) CTI > 300 V DIN IEC 112/VDE 0303 Part 1

2411221123_Broadcom-ACNT-H313-000E_C17467875.pdf

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.