input output isolation device AOTE AT3081-CuH-DE optocoupler for industrial automation and electronics

Key Attributes
Model Number: AT3081-CuH-DE
Product Custom Attributes
Number Of Channels:
1
Power Dissipation:
330mW
Operating Temperature:
-55℃~+110℃
Static Dv/dt:
600V/us
Output Current(It(rms)):
100mA
Isolation Voltage(Vrms):
5kV
Forward Current:
60mA
Load Voltage:
800V
Current - Surge(Itsm):
1A
Output Type:
TRIAC
Voltage - Forward(Vf):
1.23V
Number Of Terminals:
6
Zero Crossing Circuit:
Yes
Holding Current (Ih):
0.28mA
Mfr. Part #:
AT3081-CuH-DE
Package:
DIP-6
Product Description

Product Overview

The AOTE AT303X, AT304X, AT306X, and AT308X series optocouplers leverage high-efficiency photoelectric conversion technology and advanced packaging processes to provide reliable input-output isolation. These optocouplers are available in DIP and SMD package types, catering to diverse application requirements across industrial automation, consumer electronics, and power systems. They offer robust isolation with a voltage rating of 5000Vrms and are designed to meet stringent environmental regulations.

Product Attributes

  • Brand: AOTE
  • Product Series: AT303X, AT304X, AT306X, AT308X
  • Certifications: ROHS, REACH, HF compliant
  • Environmental Compliance: Halogen-free (indicated by 'H' in marking)
  • Package Types: DIP, SMD

Technical Specifications

Model Series Specification Rating Unit Notes
General Input-Output Isolation Voltage 5000 Vrms Vios
Creepage Distance >7.0 mm
Input-Output Insulation Thickness >0.4 mm
Absolute Maximum Ratings (Ta =25) Input Forward Current 60 mA IF
Input Backward Voltage 6 V VR
Input Power Dissipation 70 mW PD
Output Power Dissipation 300 mW PC
Model Specific VDRM Off-state output terminal voltage V
AT303X 250 V VDRM
AT304X 400 V VDRM
AT306X 600 V VDRM
AT308X 800 V VDRM
Absolute Maximum Ratings (Ta =25) Peak repetitive surge current (pw=100s,120pps) 1 A ITSM
On-state current (root mean square value) 100 mA IT(RMS)
Operating Temperature -55 ~ +110 Topr
Storage Temperature -55 ~ +125 Tstg
Soldering Temperature 260 Tsol
Recommended Operating Conditions Forward Current 5 - 15 mA IF
Product Characteristic Parameters (Ta =25) Forward Voltage - 1.23 - 1.5 V VF (IF =20mA)
Off-state peak current (AT303X) - - 100 nA IDRM1 (VDRM =Rated VDRM, IF = 0mA)
Off-state peak current (AT304X, AT306X, AT308X) - - 500 nA IDRM1 (VDRM =Rated VDRM, IF = 0mA)
On-state peak voltage - - 3 V VTM (ITM=100mA peak, IF = Rated IFT)
Critical rise rate of off-state voltage (AT303X) 1000 - - V/s dv/dt (VPEAK =Rated VDRM, IF =0)
Critical rise rate of off-state voltage (AT304X, AT306X, AT308X) 600 - - V/s dv/dt (VPEAK =Rated VDRM, IF =0)
Suppression voltage - - 20 V VInh (IF = Rated IFT)
Leakage current in suppression state - - 500 uA IDRM2 (IF = Rated IFT, VDRM=Rated VDRM, Off state)
Transfer Characteristics LED trigger current (AT3031) - - 15 mA IFT (Main terminal Voltage =3V)
LED trigger current (AT3032, AT3042, AT3062, AT3082) - - 10 mA IFT (Main terminal Voltage =3V)
LED trigger current (AT3033, AT3043, AT3063, AT3083) - - 5 mA IFT (Main terminal Voltage =3V)
Maintain current - - 280 uA IH
Packaging (SMD6) Quantity per Reel 1000 pcs
Packaging (DIP6) Quantity per Tube 65 pcs

Application Scenarios

  • Industrial Automation and Control
  • PLC and frequency converters, servo drive systems, industrial robots
  • Zero crossing products for AC voltage regulation
  • Household appliances and consumer electronics
  • Motor forward and reverse, heating control, speed regulation
  • Dimming control in lighting systems
  • Power System and Energy Management
  • Rectification, transformer protection, and power grid monitoring
  • Uninterruptible power supply (UPS) and power protection equipment
  • Medical and Special Scenarios
  • Isolation and circuit protection for devices like heart rate monitors and X-ray machines

2508011705_AOTE-AT3081-CuH-DE_C20612752.pdf

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.