thyristor optocoupler AOTE AT3051-CuH-DE offering high input output isolation voltage for industrial automation

Key Attributes
Model Number: AT3051-CuH-DE
Product Custom Attributes
Number Of Channels:
1
Power Dissipation:
330mW
Operating Temperature:
-55℃~+110℃
Isolation Voltage(Vrms):
5kV
Static Dv/dt:
100V/us
Output Current(It(rms)):
100mA
Forward Current:
60mA
Current - Surge(Itsm):
1A
Output Type:
TRIAC
Voltage - Forward(Vf):
1.23V
Number Of Terminals:
6
Zero Crossing Circuit:
No
Holding Current (Ih):
0.25mA
Mfr. Part #:
AT3051-CuH-DE
Package:
DIP-6
Product Description

Product Overview

The AOTE AT301X, AT302X, AT305X, and AT307X series optocouplers leverage high-efficiency photoelectric conversion technology and advanced packaging processes to provide reliable input-output isolation. These optocouplers are available in DIP and SMD package types, catering to diverse application needs across industrial automation, consumer electronics, and power systems. They offer robust isolation capabilities, supporting high isolation voltages and various off-state output terminal voltages.

Product Attributes

  • Brand: AOTE
  • Certifications: ROHS, REACH, HF
  • Package Types: DIP, SMD
  • Moisture Sensitivity Level: Class 1 (MSL Class 1)

Technical Specifications

Model Series Product Description Input-Output Isolation Voltage (Vrms) Off-State Output Terminal Voltage (VDRM) Peak Repetitive Surge Current (ITSM) Creepage Distance (mm) Input-Output Insulation Thickness (mm)
AT301X, AT302X, AT305X, AT307X Thyristor Optocoupler 5000 800, 600, 400, 250 (Varies by model) 1 A (pw=100 s, 120pps) > 7.0 > 0.4

Absolute Maximum Ratings (Ta = 25)

Parameter Symbol Rating Unit
Input Forward Current IF 60 mA
Input Backward Voltage VR 6 V
Input Power Dissipation PD 70 mW
Input Power Dissipation Derating Factor (above 90C) PDD 3.8 mW/
Off-state output terminal voltage (AT301X) VDRM 250 V
Off-state output terminal voltage (AT302X) VDRM 400 V
Off-state output terminal voltage (AT305X) VDRM 600 V
Off-state output terminal voltage (AT307X) VDRM 800 V
Peak repetitive surge current (pw=100 s, 120pps) ITSM 1 A
On-state current (root mean square value) IT(RMS) 100 mA
Output Power Dissipation PC 300 mW
Output Power Dissipation Derating Factor (above 90C) 7.4 mW/
Isolation Voltage Viso 5000 Vrms
Operating Temperature Topr -55 to +110
Storage Temperature Tstg -55 to +125
Soldering Temperature Tsol 260

Recommended Operating Conditions

Parameter Symbol Min. Max. Unit
Forward Current IF 5 15 mA
Peak repetitive surge current (pw=100 s, 120pps) ITSM - 1 A
On-state current (root mean square value) IT(RMS) - 100 mA

Product Characteristic Parameters (Ta = 25)

Parameter Symbol Condition Min. Typ. Max. Unit
Input Forward Voltage VF IF = 20mA - 1.23 1.5 V
Input Back Current IR VR = 6V - - 10 uA
Output Off-state peak current IDRM VDRM = Rated VDRM, IF = 0mA - - 100 nA
Output On-state peak voltage VTM ITM=100mA peak, IF =Rated IFT - - 2.5 V
Critical rise rate of off-state voltage (AT301X) dv/dt VPEAK = Rated VDRM, IF =0 - 100 - V/s
Critical rise rate of off-state voltage (AT302X, AT305X) dv/dt VPEAK = 400V, IF =0 1000 - - V/s
LED trigger current (AT3020) IFT Main terminal Voltage = 3V - - 30 mA
LED trigger current (AT3011, AT3021, AT3051, AT3071) IFT Main terminal Voltage = 3V - - 15 mA
LED trigger current (AT3012, AT3022, AT3052, AT3072) IFT Main terminal Voltage = 3V - - 10 mA
LED trigger current (AT3013, AT3023, AT3053, AT3073) IFT Main terminal Voltage = 3V - - 5 mA
Maintain current IH - - 250 - uA

Application Fields

  • Industrial Automation and Control: PLC and frequency converters, servo drive systems, industrial robots.
  • Household Appliances and Consumer Electronics: Motor forward and reverse control, heating control, speed regulation, dimming control in lighting systems.
  • Power System and Energy Management: Rectification, transformer protection, power grid monitoring, uninterruptible power supply (UPS) and power protection equipment.
  • Medical and Special Scenarios: Isolation and circuit protection for devices such as heart rate monitors and X-ray machines.

Overall Dimensions

Refer to page 8 of the datasheet for detailed drawings and recommended pad layouts.

Order Code Structure

Company Code: AT (Aote)
Product Series: 30VX (301X, 302X, 305X, 307X)
Lead Frame: Cu (Copper)
Epoxy Type: H (Halogen-free)
Package: D (DIP), S (SMD)
Device Operating Temperature Range: (Special range needs to be filled in or left blank)
Internal Supplementary Code: (Number or None)

Marking Information

Marking includes AOTE LOGO, Year code (A=2018, B=2019, etc.), Week code, Internal code, and 'H' for Halogen-free.

Packing

Package Type Packing Form Quantity per Reel/Tube Quantity per Box Quantity per Carton Box Specification Carton Specification
SMD6 Reel (330mm Blue) 1000 pcs/reel 2 reels/box 10 boxes/ctn (20000 pcs/ctn) 340*60*340mm 620*360*365mm
DIP6 Tube (500*12*11mm) 65 pcs/tube 50 tubes/box 10 boxes/ctn (32500 pcs/ctn) 525*128*56mm 535*275*300mm

Reliability Test Items

Test Item Reference Standard Test Conditions Time Quantity Criterion
Solderability JESD22-B102 Tsol=(2455), t=5s; 1 time - 22 0/22
Resistance to Soldering Heat JESD22-A106 Tsol=(2605), t=10s; 3 times - 22 0/22
ESD-HBM JESD22-A114 Ta=25, HBM (2000V) Positive & Negative 3 times each - 10 0/10
High Temperature Storage JESD22-A103 Ta=125 1000h 22 0/22
Low Temperature Storage JESD22-A119 Ta= -55 1000h 22 0/22
Thermal Shock JESD22-A104 -55(15min)125(15min) 300 cycles - 22 0/22
Lifespan Test (Room Temp) JESD22-A108 Ta=25, IF=50mA, Vcc=5V 1000h 22 0/22
DC Operating Life (High Temp) JESD22-A108 Ta=110, IF=20mA, Vcc=5V 1000h 76 0/76
High Temperature High Humidity Bias JESD22-A101 Ta =85, RH=85%, IF=0mA, VCE=64V 1000h 22 0/22
High Temperature Bias JESD22-A108 Ta =110, IF=0mA, VCE=80V 1000h 22 0/22
High Pressure Steam Test JESD22-A102 P=15PSIG, 121, 100%RH 96h 22 0/22

Soldering Profiles

Refer to pages 11 for Solder Reflow Profile, Wave Soldering Profile, and Hand Soldering Iron requirements.

Attention

AOTE implements dynamic technical updates. Specifications are subject to change. Refer to the official website for the latest version. Users must strictly adhere to specified conditions. Failures caused by misuse (overload, high temperature, incompatible circuits) are excluded from warranty. Contact technical support for customized validation in critical applications (medical devices, industrial control). This document is valid until Dec 31, 2025. Updates will be notified on the official website.


2508011705_AOTE-AT3051-CuH-DE_C20612728.pdf

Contact Our Experts And Get A Free Consultation!