Halogen-free epoxy SOP4 optocoupler copper lead frame AOTE ATM3063-CuH-SE for industrial electronics

Key Attributes
Model Number: ATM3063-CuH-SE
Product Custom Attributes
Number Of Channels:
1
Power Dissipation:
330mW
Operating Temperature:
-55℃~+110℃
Isolation Voltage(Vrms):
3.75kV
Static Dv/dt:
1000V/us
Output Current(It(rms)):
100mA
Forward Current:
60mA
Load Voltage:
600V
Current - Surge(Itsm):
1A
Output Type:
TRIAC
Voltage - Forward(Vf):
1.3V
Number Of Terminals:
4
Zero Crossing Circuit:
Yes
Mfr. Part #:
ATM3063-CuH-SE
Package:
SOP-4
Product Description
Thyristor Optocoupler ATM303X, ATM304X, ATM306X, ATM308X

Product Overview

The AOTE ATM303X, ATM304X, ATM306X, and ATM308X series optocouplers utilize high-efficiency photoelectric conversion technology and advanced packaging processes to provide reliable input-output isolation. Designed for SOP4 package types, these devices are suitable for diverse application requirements across industrial automation, consumer electronics, and power systems. They offer robust isolation voltage and compliance with environmental regulations.

Product Attributes

  • Brand: AOTE
  • Product Series: ATM303X, ATM304X, ATM306X, ATM308X
  • Package Type: SOP4
  • Certifications: ROHS, REACH, HF compliant
  • Environmental Compliance: Moisture Sensitivity Level (MSL) Class 1
  • Lead Frame Material: Copper (Cu)
  • Epoxy Type: Halogen-free (H)

Technical Specifications

Parameter Symbol Model Rating Unit Condition
Product Features
Input-Output Isolation Voltage Vios All 5000 Vrms
Off-state Output Terminal Voltage VDRM ATM303X 250 V
VDRM ATM304X 400 V
VDRM ATM306X 600 V
VDRM ATM308X 800 V
Peak Repetitive Surge Current ITSM All 1 A pw=100 s, 120pps
Creepage Distance All >7.0 mm
Input-Output Insulation Thickness All >0.4 mm
Absolute Maximum Ratings (Ta =25)
Forward Current IF Input 60 mA
Backward Voltage VR Input 6 V
Power Dissipation PD Input 70 mW
Power Dissipation Derating factor (above Ta = 90C) PDD Input 3.8 mW/
Off-state output terminal voltage VDRM ATM303X 250 V
VDRM ATM304X 400 V
VDRM ATM306X 600 V
VDRM ATM308X 800 V
Peak repetitive surge current (pw=100 s,120pps) ITSM All 1 A
On-state current (root mean square value) IT(RMS) All 100 mA
Power Dissipation PC Output 300 mW
Power dissipation Derating factor (above Ta = 90C) Output 7.4 mW/
Isolation Voltage Viso All 5000 Vrms
Operating Temperature Topr All -55 to +110
Storage Temperature Tstg All -55 to +125
Soldering Temperature Tsol All 260
Recommended Operating Conditions
Forward Current IF All 5 to 15 mA
Peak repetitive surge current (pw=100 s,120pps) ITSM All - to 1 A
On-state current (root mean square value) IT(RMS) All - to 100 mA
Product Characteristic Parameters (Ta =25)
Forward Voltage VF All - to 1.5 V IF =20mA
Back current IR All - to 10 uA VR =6V
Off-state peak current IDRM1 ATM303X - to 100 nA VDRM =Rated VDRM, IF = 0mA
IDRM1 ATM304X, ATM306X - to 500 nA VDRM =Rated VDRM, IF = 0mA
IDRM1 ATM308X - to 500 nA VDRM =Rated VDRM, IF = 0mA
On-state peak voltage VTM All - to 3 V ITM=100mA peak, IF = Rated IFT
Critical rise rate of off-state voltage dv/dt ATM303X 1000 V/s VPEAK =Rated VDRM, IF =0
dv/dt ATM304X, ATM306X, ATM308X 600 V/s VPEAK =Rated VDRM, IF =0
Suppression voltage VInh All - to 20 V IF = Rated IFT
Leakage current in suppression state IDRM2 All - to 500 uA IF = Rated IFT, VDRM=Rated VDRM, Off state
LED trigger current IFT ATM3031 - to 15 mA Main terminal Voltage =3V
IFT ATM3041, ATM3061, ATM3081 - to 15 mA Main terminal Voltage =3V
IFT ATM3032 - to 10 mA Main terminal Voltage =3V
IFT ATM3042, ATM3062, ATM3082 - to 10 mA Main terminal Voltage =3V
IFT ATM3033 - to 5 mA Main terminal Voltage =3V
IFT ATM3043, ATM3063, ATM3083 - to 5 mA Main terminal Voltage =3V
Maintain current IH All - to 280 uA
Application Areas
Industrial Automation and Control; PLC and frequency converter, servo drive system, industrial robot
Household appliances and consumer electronics: Motor forward and reverse heating control, speed regulation, etc. Used for dimming control in lighting systems.
Power System and Energy Management: Used for rectification, transformer protection, and power grid monitoring. Applied to uninterruptible power supply (UPS) and power protection equipment.
Medical and Special Scenarios: Used for isolation and circuit protection of devices such as heart rate monitors and X-ray machines.